{
  "Spase": {
    "xmlns": "http://www.spase-group.org/data/schema",
    "xmlns:xsi": "http://www.w3.org/2001/XMLSchema-instance",
    "xsi:schemaLocation": "http://www.spase-group.org/data/schema https://www.spase-group.org/data/schema/spase-2_4_0.xsd",
    "Version": "2.4.0",
    "NumericalData": {
      "ResourceID": "spase://NASA/NumericalData/ParkerSolarProbe/FIELDS/RFS/Level2/HFR/PT7S",
      "ResourceHeader": {
        "ResourceName": "Parker Solar Probe, FIELDS Radio Frequency Spectrometer, RFS, High Frequency Receiver, HFR, Spectra, Level 2 (L2), 7 s and 56 s Data",
        "DOI": "https://doi.org/10.48322/gf9t-4082",
        "ReleaseDate": "2022-05-25T12:34:56.789",
        "RevisionHistory": {
          "RevisionEvent": [
            {
              "ReleaseDate": "2021-05-08T21:30:02",
              "Note": "PSP FIELDS: Initial SPASE XML resource description submission, metadata generated by LFB"
            },
            {
              "ReleaseDate": "2022-05-25T12:34:56.789",
              "Note": "PSP FIELDS: Updated to SPASE Version 2.4.0, FIELDS data release InformationURLs added, FIELDS data quality flag definition updated, metadata generated by LFB"
            }
          ]
        },
        "Description": "PSP FIELDS Radio Frequency Spectrometer, RFS, High Frequency Receiver, HFR, Data:\n\nThe RFS is the high frequency component of the FIELDS experiment on the Parker Solar Probe spacecraft, see reference [1]. For a full description of the FIELDS experiment, see reference [2]. For a description of the RFS, see reference [3].\n\nThe RFS produces auto and cross spectral data products in two frequency ranges, the Low Frequency Reciever range and the High Frequency Receiver range. Telemetered spectral data products for both HFR and LFR contain 64 frequency bins, with the LFR typically covering a frequency range from 10.5 kHz to 1.7 MHz, and the HFR covering from 1.3 MHz to 19.2 MHz, with approximately logarithmically spaced bins. LFR high-resolution spectra contain 32 finely spaced frequency bins near the plasma frequency. The exact frequency bins are selectable and are included as metadata variables in this file.\n\nThe Level 2 data products contained in this data file have been calibrated for the preamp and RFS analog section response, the Polyphase Filter Bank, PFB, and the Fast Fourier Transform, FFT, spectral processing as described in reference [3]. Corrections for base capacitance and antenna effective length have not been applied. These corrections will be applied in Level 3 RFS data. Therefore, the units for all spectral quantities are given in V^2/Hz.\n\nThe time resolution of the RFS data vary with instrument mode. During encounter, which is when PSP is within 0.25 astronomical units, AU, of the Sun, the cadence for RFS HFR and LFR spectra is typically about 7 s. During cruise mode, which is the default mode for operations outside of 0.25 AU, the cadence for HFR and LFR spectra is about 56 s.\n\nReferences:\n\n* 1) Fox, N.J., Velli, M.C., Bale, S.D., et al., Space Sci Rev (2016), 204:7, DOI:10.1007/s11214-015-0211-6\n* 2) Bale, S.D., Goetz, K., Harvey, P.R., et al., Space Sci Rev (2016), 204:49, DOI:10.1007/s11214-016-0244-5\n* 3) Pulupa, M., Bale, S.D., Bonnell, J.W., et al., JGR Space Physics (2017), 122, 2836-2854, DOI:10.1002/2016JA023345",
        "Acknowledgement": "Please acknowledge S.D. Bale for use of the Data. \n\nPSP/FIELDS Rules of the Road available at http://fields.ssl.berkeley.edu/rules/",
        "PublicationInfo": {
          "Authors": "Bale, Stuart D ",
          "PublicationDate": "2020-01-01T00:00:00Z",
          "PublishedBy": "NASA Space Physics Data Facility"
        },
        "Contact": [
          {
            "PersonID": "spase://SMWG/Person/Stuart.D.Bale",
            "Role": "PrincipalInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Robert.M.Candey",
            "Role": "MetadataContact"
          },
          {
            "PersonID": "spase://SMWG/Person/Lee.Frost.Bargatze",
            "Role": "MetadataContact"
          }
        ],
        "InformationURL": [
          {
            "Name": "PSP FIELDS Instrument Suite, Space Science Review Publication",
            "URL": "https://doi.org/10.1007/s11214-016-0244-5",
            "Description": "Parker Solar Probe, PSP, FIELDS Instrument Suite Description: Bale, S.D., Goetz, K., Harvey, P.R. et al., The FIELDS Instrument Suite for Solar Probe Plus, Space Sci Rev 204, 49-82 (2016)"
          },
          {
            "Name": "PSP FIELDS Instrument Suite, Digital Fields Board, JGR Space Physics Publication",
            "URL": "https://doi.org/10.1002/2016JA022344",
            "Description": "Parker Solar Probe, PSP, FIELDS Instrument Suite, Digital Fields Board, DFB, Description: Malaspina, D.M., Ergun, R.E., Bolton, M. et al., The Digital Fields Board for the FIELDS Instrument Suite on the Solar Probe Plus Mission: Analog and Digital signal Processing, JGR Space Physics, 121, 5088-5096 (2016)"
          },
          {
            "Name": "Parker Solar Probe, PSP, Satellite Operations Center, FIELDS RFS, LFR and HFR, data web site, UC Berkeley",
            "URL": "https://fields.ssl.berkeley.edu/data/",
            "Description": "Parker Solar Probe, PSP, FIELDS Satellite Operations Center, SOC, FIELDS Radio Frequency Spectrometer, RFS, Low Frequency Reciever, LFR, and High Frequency Receiver, HFR, data web site, hosted at the University of California, Berkeley"
          },
          {
            "Name": "PSP FIELDS Instrument Suite, Rules of the Road, SOC Web Site, UC Berkeley",
            "URL": "https://fields.ssl.berkeley.edu/rules/",
            "Description": "Parker Solar Probe, PSP, FIELDS Instrument Suite, Rules of the Road, Spacecraft Operations Center, SOC, Web Site, UC Berkeley"
          },
          {
            "Name": "PSP Mission Overview, APL, JHU",
            "URL": "http://parkersolarprobe.jhuapl.edu/The-Mission/index.php",
            "Description": "Parker Solar Probe, PSP, Mission Overview, hosted by the Applied Physics Laboratory, Johns Hopkins University"
          },
          {
            "Name": "Release notes for PSP/FIELDS data release 5.1",
            "URL": "https://fields.ssl.berkeley.edu/2020/10/release-notes-for-psp-fields-release-5-1/",
            "Description": "PSP/FIELDS data release 5.1, on October 19, 2020, updates the dfb_dbm_scm and dfb_wf_dvdc data types to version 3. The new data versions contain significant corrections to the previously released data."
          },
          {
            "Name": "Release notes for PSP/FIELDS data release 7",
            "URL": "https://fields.ssl.berkeley.edu/2021/04/release-notes-for-psp-fields-data-release-7/",
            "Description": "PSP/FIELDS data release 7, on April 4, 2021, includes data from PSP Encounter 6 (September 2020). All data up to and including December 2020 are now publicly available. For this data release, all DFB cross spectra have been reprocessed (with a new version number), and a subset of MAG data has also been reprocessed (with a new version number)."
          },
          {
            "Name": "Release notes for PSP/FIELDS data release 8",
            "URL": "https://fields.ssl.berkeley.edu/2021/06/release-notes-for-psp-fields-data-release-8/",
            "Description": "PSP/FIELDS data release 8, on June 28, 2021, includes survey data from PSP Encounter 7 and Venus Gravity assist 4. Several data sets have been updated in release 8."
          },
          {
            "Name": "Release notes for PSP/FIELDS data release 9",
            "URL": "https://fields.ssl.berkeley.edu/2021/10/release-notes-for-psp-fields-data-release-9/",
            "Description": "PSP/FIELDS Data Release 9, on October 29, 2021, includes select data from Encounter 7 (perihelion January 2021), and survey and select data from Encounter 8 (perihelion April 2021)."
          },
          {
            "Name": "Release notes for PSP/FIELDS data release 10",
            "URL": "https://fields.ssl.berkeley.edu/2022/02/release-notes-for-psp-fields-data-release-10/",
            "Description": "PSP/FIELDS Data Release 10, on February 7, 2022, includes survey and select data from Encounter 9 (perihelion August 2021)."
          },
          {
            "Name": "Release notes for PSP/FIELDS data release 11",
            "URL": "https://fields.ssl.berkeley.edu/2022/04/release-notes-for-psp-fields-data-release-11/",
            "Description": "PSP/FIELDS Data Release 11, on April 25, 2022, includes survey and select data from Encounter 10 (perihelion November 2021), and survey and select data from Venus Gravity Assist 5 (October 2021)."
          }
        ],
        "PriorID": "spase://VSPO/NumericalData/ParkerSolarProbe/FIELDS/RFS/Level2/HFR/PT7S"
      },
      "AccessInformation": [
        {
          "RepositoryID": "spase://SMWG/Repository/NASA/GSFC/SPDF",
          "Availability": "Online",
          "AccessRights": "Open",
          "AccessURL": [
            {
              "Name": "FTPS from SPDF (not with most browsers)",
              "URL": "ftps://spdf.gsfc.nasa.gov/pub/data/psp/fields/l2/rfs_hfr/",
              "Description": "Access to Data in CDF Format via ftp from SPDF"
            },
            {
              "Name": "HTTPS from SPDF",
              "URL": "https://spdf.gsfc.nasa.gov/pub/data/psp/fields/l2/rfs_hfr/",
              "Description": "Access to Data in CDF Format via http from SPDF"
            },
            {
              "Name": "CDAWeb",
              "URL": "https://cdaweb.gsfc.nasa.gov/cgi-bin/eval2.cgi?dataset=PSP_FLD_L2_RFS_HFR&index=sp_phys",
              "ProductKey": "PSP_FLD_L2_RFS_HFR",
              "Description": "Access to ASCII, CDF, and Plots via NASA/GSFC CDAWeb"
            }
          ],
          "Format": "CDF",
          "Encoding": "None",
          "Acknowledgement": "Please acknowledge S.D. Bale. Please acknowledge the Data Providers and CDAWeb when using these Data."
        },
        {
          "RepositoryID": "spase://SMWG/Repository/NASA/GSFC/SPDF",
          "Availability": "Online",
          "AccessRights": "Open",
          "AccessURL": {
            "Name": "CDAWeb HAPI Server",
            "URL": "https://cdaweb.gsfc.nasa.gov/hapi",
            "Style": "HAPI",
            "ProductKey": [
              "PSP_FLD_L2_RFS_HFR@0",
              "PSP_FLD_L2_RFS_HFR@1",
              "PSP_FLD_L2_RFS_HFR@2",
              "PSP_FLD_L2_RFS_HFR@3",
              "PSP_FLD_L2_RFS_HFR@4",
              "PSP_FLD_L2_RFS_HFR@5",
              "PSP_FLD_L2_RFS_HFR@6",
              "PSP_FLD_L2_RFS_HFR@7",
              "PSP_FLD_L2_RFS_HFR@8"
            ],
            "Description": "Web Service to this product using the HAPI interface."
          },
          "Format": "CSV",
          "Acknowledgement": "Please acknowledge S.D. Bale. Please acknowledge the Data Providers and CDAWeb when using these Data."
        }
      ],
      "ProcessingLevel": "Calibrated",
      "InstrumentID": "spase://SMWG/Instrument/ParkerSolarProbe/FIELDS/RFS/HFR",
      "MeasurementType": [
        "InstrumentStatus",
        "Spectrum",
        "Waves.Passive"
      ],
      "TemporalDescription": {
        "TimeSpan": {
          "StartDate": "2018-10-06T00:00:00.000",
          "RelativeStopDate": "-P7M"
        },
        "Cadence": "PT7S"
      },
      "Parameter": [
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 0: V1-V2",
          "ParameterKey": "epoch_hfr_auto_averages_ch0_V1V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 0: V1-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V1V2",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch0 V1V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 0: V1-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1V2",
          "ParameterKey": "frequency_hfr_auto_averages_ch0_V1V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 0: V1-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V1V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V1V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 0: V1-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V1V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 0: V1-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V1V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 0: V1-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V1V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V1V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 0: V1-V3",
          "ParameterKey": "epoch_hfr_auto_averages_ch0_V1V3",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1-V3 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 0: V1-V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V1V3",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1-V3 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch0 V1V3 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 0: V1-V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1V3",
          "ParameterKey": "frequency_hfr_auto_averages_ch0_V1V3",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1-V3 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 0: V1-V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V1V3_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1-V3 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V1V3 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 0: V1-V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V1V3_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 0: V1-V3 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V1V3 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 0: V1-V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V1V3_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1-V3 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V1V3 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 0: V2-V4",
          "ParameterKey": "epoch_hfr_auto_averages_ch0_V2V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V2-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 0: V2-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V2V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V2V4",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V2-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch0 V2V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 0: V2-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V2V4",
          "ParameterKey": "frequency_hfr_auto_averages_ch0_V2V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V2-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 0: V2-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V2V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V2V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V2-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V2V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 0: V2-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V2V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V2V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 0: V2-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V2V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 0: V2-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V2V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V2V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V2-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V2V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 0: SCM",
          "ParameterKey": "epoch_hfr_auto_averages_ch0_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 0: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_SCM",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch0 SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 0: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_SCM",
          "ParameterKey": "frequency_hfr_auto_averages_ch0_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 0: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 0: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 0: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 0: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 0: V1",
          "ParameterKey": "epoch_hfr_auto_averages_ch0_V1",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 0: V1",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V1",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch0 V1 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 0: V1",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1",
          "ParameterKey": "frequency_hfr_auto_averages_ch0_V1",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 0: V1",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V1_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V1 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 0: V1",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V1_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 0: V1 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V1 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 0: V1",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V1",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V1_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V1 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V1 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 0: V3",
          "ParameterKey": "epoch_hfr_auto_averages_ch0_V3",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V3 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 0: V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V3",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V3 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch0 V3 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 0: V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V3",
          "ParameterKey": "frequency_hfr_auto_averages_ch0_V3",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V3 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 0: V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V3_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V3 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V3 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 0: V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V3_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 0: V3 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V3 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 0: V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_V3_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: V3 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 V3 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 0: GND",
          "ParameterKey": "epoch_hfr_auto_averages_ch0_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 0: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_GND",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch0 GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 0: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_GND",
          "ParameterKey": "frequency_hfr_auto_averages_ch0_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 0: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 0: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 0: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 0: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH0_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch0_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 0: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch0 GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_auto_averages_ch1_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V3V4",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch1 V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V3V4",
          "ParameterKey": "frequency_hfr_auto_averages_ch1_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_auto_averages_ch1_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V3V2",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch1 V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V3V2",
          "ParameterKey": "frequency_hfr_auto_averages_ch1_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_auto_averages_ch1_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V1V4",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch1 V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V1V4",
          "ParameterKey": "frequency_hfr_auto_averages_ch1_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_auto_averages_ch1_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_SCM",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch1 SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_SCM",
          "ParameterKey": "frequency_hfr_auto_averages_ch1_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_auto_averages_ch1_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V2",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch1 V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V2",
          "ParameterKey": "frequency_hfr_auto_averages_ch1_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_auto_averages_ch1_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V4",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch1 V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V4",
          "ParameterKey": "frequency_hfr_auto_averages_ch1_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Averages, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_auto_averages_ch1_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Averages, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_GND",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_averages ch1 GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "Average",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Averages, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_GND",
          "ParameterKey": "frequency_hfr_auto_averages_ch1_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Averages, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Averages, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Averages, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Averages, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_AVERAGES_CH1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_averages_ch1_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Averages, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_averages ch1 GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 0: V1-V2",
          "ParameterKey": "epoch_hfr_auto_peaks_ch0_V1V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 0: V1-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V1V2",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch0 V1V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 0: V1-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1V2",
          "ParameterKey": "frequency_hfr_auto_peaks_ch0_V1V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 0: V1-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V1V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V1V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 0: V1-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V1V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 0: V1-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V1V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 0: V1-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V1V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V1V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 0: V1-V3",
          "ParameterKey": "epoch_hfr_auto_peaks_ch0_V1V3",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1-V3 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 0: V1-V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V1V3",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1-V3 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch0 V1V3 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 0: V1-V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1V3",
          "ParameterKey": "frequency_hfr_auto_peaks_ch0_V1V3",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1-V3 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 0: V1-V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V1V3_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1-V3 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V1V3 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 0: V1-V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V1V3_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 0: V1-V3 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V1V3 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 0: V1-V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V1V3_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1-V3 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V1V3 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 0: V2-V4",
          "ParameterKey": "epoch_hfr_auto_peaks_ch0_V2V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V2-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 0: V2-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V2V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V2V4",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V2-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch0 V2V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 0: V2-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V2V4",
          "ParameterKey": "frequency_hfr_auto_peaks_ch0_V2V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V2-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 0: V2-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V2V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V2V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V2-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V2V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 0: V2-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V2V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V2V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 0: V2-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V2V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 0: V2-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V2V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V2V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V2-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V2V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 0: SCM",
          "ParameterKey": "epoch_hfr_auto_peaks_ch0_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 0: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_SCM",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch0 SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 0: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_SCM",
          "ParameterKey": "frequency_hfr_auto_peaks_ch0_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 0: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 0: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 0: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 0: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 0: V1",
          "ParameterKey": "epoch_hfr_auto_peaks_ch0_V1",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 0: V1",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V1",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch0 V1 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 0: V1",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1",
          "ParameterKey": "frequency_hfr_auto_peaks_ch0_V1",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 0: V1",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V1_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V1 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 0: V1",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V1_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 0: V1 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V1 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 0: V1",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V1",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V1_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V1 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V1 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 0: V3",
          "ParameterKey": "epoch_hfr_auto_peaks_ch0_V3",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V3 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 0: V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V3",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V3 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch0 V3 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 0: V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V3",
          "ParameterKey": "frequency_hfr_auto_peaks_ch0_V3",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V3 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 0: V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V3_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V3 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V3 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 0: V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V3_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 0: V3 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V3 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 0: V3",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_V3",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_V3_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: V3 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 V3 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 0: GND",
          "ParameterKey": "epoch_hfr_auto_peaks_ch0_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 0: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_GND",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch0 GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 0: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_GND",
          "ParameterKey": "frequency_hfr_auto_peaks_ch0_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 0: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 0: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 0: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 0: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH0_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch0_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 0: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch0 GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_auto_peaks_ch1_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V3V4",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch1 V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V3V4",
          "ParameterKey": "frequency_hfr_auto_peaks_ch1_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_auto_peaks_ch1_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V3V2",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch1 V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V3V2",
          "ParameterKey": "frequency_hfr_auto_peaks_ch1_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_auto_peaks_ch1_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V1V4",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch1 V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V1V4",
          "ParameterKey": "frequency_hfr_auto_peaks_ch1_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_auto_peaks_ch1_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_SCM",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch1 SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_SCM",
          "ParameterKey": "frequency_hfr_auto_peaks_ch1_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_auto_peaks_ch1_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V2",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch1 V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V2",
          "ParameterKey": "frequency_hfr_auto_peaks_ch1_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_auto_peaks_ch1_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V4",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch1 V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V4",
          "ParameterKey": "frequency_hfr_auto_peaks_ch1_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Auto Spectra, Peaks, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_auto_peaks_ch1_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Auto Spectra, Peaks, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_GND",
          "Description": "High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR auto_peaks ch1 GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Peak"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Auto Spectra, Peaks, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_GND",
          "ParameterKey": "frequency_hfr_auto_peaks_ch1_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Auto Spectra, Peaks, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Auto Spectra, Peaks, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Auto Spectra, Peaks, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Auto Spectra, Peaks, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_AUTO_PEAKS_CH1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_auto_peaks_ch1_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Auto Spectra, Peaks, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR auto_peaks ch1 GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_im_V1V2_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V2_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V3V4",
          "ParameterKey": "frequency_hfr_cross_im_V1V2_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_im_V1V2_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V2_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V3V2",
          "ParameterKey": "frequency_hfr_cross_im_V1V2_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_im_V1V2_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V2_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V1V4",
          "ParameterKey": "frequency_hfr_cross_im_V1V2_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_im_V1V2_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V2_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_SCM",
          "ParameterKey": "frequency_hfr_cross_im_V1V2_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_im_V1V2_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V2_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V2",
          "ParameterKey": "frequency_hfr_cross_im_V1V2_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_im_V1V2_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V2_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V4",
          "ParameterKey": "frequency_hfr_cross_im_V1V2_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_im_V1V2_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V2_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_GND",
          "ParameterKey": "frequency_hfr_cross_im_V1V2_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V2_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V2_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_im_V1V3_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V3_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V3V4",
          "ParameterKey": "frequency_hfr_cross_im_V1V3_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_im_V1V3_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V3_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V3V2",
          "ParameterKey": "frequency_hfr_cross_im_V1V3_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_im_V1V3_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V3_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V1V4",
          "ParameterKey": "frequency_hfr_cross_im_V1V3_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_im_V1V3_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V3_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_SCM",
          "ParameterKey": "frequency_hfr_cross_im_V1V3_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_im_V1V3_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V3_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V2",
          "ParameterKey": "frequency_hfr_cross_im_V1V3_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_im_V1V3_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V3_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V4",
          "ParameterKey": "frequency_hfr_cross_im_V1V3_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_im_V1V3_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1V3_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_GND",
          "ParameterKey": "frequency_hfr_cross_im_V1V3_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1V3_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1V3_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_im_V2V4_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V2V4_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V3V4",
          "ParameterKey": "frequency_hfr_cross_im_V2V4_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_im_V2V4_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V2V4_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V3V2",
          "ParameterKey": "frequency_hfr_cross_im_V2V4_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_im_V2V4_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V2V4_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V1V4",
          "ParameterKey": "frequency_hfr_cross_im_V2V4_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_im_V2V4_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V2V4_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_SCM",
          "ParameterKey": "frequency_hfr_cross_im_V2V4_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_im_V2V4_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V2V4_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V2",
          "ParameterKey": "frequency_hfr_cross_im_V2V4_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_im_V2V4_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V2V4_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V4",
          "ParameterKey": "frequency_hfr_cross_im_V2V4_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_im_V2V4_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V2V4_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_GND",
          "ParameterKey": "frequency_hfr_cross_im_V2V4_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V2V4_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V2V4_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_im_SCM_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im SCM_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V3V4",
          "ParameterKey": "frequency_hfr_cross_im_SCM_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_im_SCM_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im SCM_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V3V2",
          "ParameterKey": "frequency_hfr_cross_im_SCM_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_im_SCM_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im SCM_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V1V4",
          "ParameterKey": "frequency_hfr_cross_im_SCM_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_im_SCM_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im SCM_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_SCM",
          "ParameterKey": "frequency_hfr_cross_im_SCM_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_im_SCM_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im SCM_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V2",
          "ParameterKey": "frequency_hfr_cross_im_SCM_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_im_SCM_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im SCM_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V4",
          "ParameterKey": "frequency_hfr_cross_im_SCM_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_im_SCM_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im SCM_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_GND",
          "ParameterKey": "frequency_hfr_cross_im_SCM_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_SCM_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im SCM_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_im_V1_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V3V4",
          "ParameterKey": "frequency_hfr_cross_im_V1_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_im_V1_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V3V2",
          "ParameterKey": "frequency_hfr_cross_im_V1_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_im_V1_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V1V4",
          "ParameterKey": "frequency_hfr_cross_im_V1_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_im_V1_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_SCM",
          "ParameterKey": "frequency_hfr_cross_im_V1_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_im_V1_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V2",
          "ParameterKey": "frequency_hfr_cross_im_V1_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_im_V1_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V4",
          "ParameterKey": "frequency_hfr_cross_im_V1_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_im_V1_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V1_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_GND",
          "ParameterKey": "frequency_hfr_cross_im_V1_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V1_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V1_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_im_V3_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V3_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V3V4",
          "ParameterKey": "frequency_hfr_cross_im_V3_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_im_V3_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V3_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V3V2",
          "ParameterKey": "frequency_hfr_cross_im_V3_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_im_V3_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V3_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V1V4",
          "ParameterKey": "frequency_hfr_cross_im_V3_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_im_V3_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V3_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_SCM",
          "ParameterKey": "frequency_hfr_cross_im_V3_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_im_V3_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V3_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V2",
          "ParameterKey": "frequency_hfr_cross_im_V3_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_im_V3_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V3_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V4",
          "ParameterKey": "frequency_hfr_cross_im_V3_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_im_V3_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im V3_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_GND",
          "ParameterKey": "frequency_hfr_cross_im_V3_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_V3_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im V3_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_im_GND_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im GND_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V3V4",
          "ParameterKey": "frequency_hfr_cross_im_GND_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_im_GND_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im GND_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V3V2",
          "ParameterKey": "frequency_hfr_cross_im_GND_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_im_GND_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im GND_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V1V4",
          "ParameterKey": "frequency_hfr_cross_im_GND_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_im_GND_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im GND_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_SCM",
          "ParameterKey": "frequency_hfr_cross_im_GND_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_im_GND_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im GND_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V2",
          "ParameterKey": "frequency_hfr_cross_im_GND_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_im_GND_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im GND_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V4",
          "ParameterKey": "frequency_hfr_cross_im_GND_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_im_GND_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_im GND_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_GND",
          "ParameterKey": "frequency_hfr_cross_im_GND_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Imag. Part, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_IM_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_im_GND_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Imaginary Part, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_im GND_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_re_V1V2_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V2_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V3V4",
          "ParameterKey": "frequency_hfr_cross_re_V1V2_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_re_V1V2_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V2_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V3V2",
          "ParameterKey": "frequency_hfr_cross_re_V1V2_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_re_V1V2_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V2_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V1V4",
          "ParameterKey": "frequency_hfr_cross_re_V1V2_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_re_V1V2_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V2_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_SCM",
          "ParameterKey": "frequency_hfr_cross_re_V1V2_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_re_V1V2_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V2_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V2",
          "ParameterKey": "frequency_hfr_cross_re_V1V2_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_re_V1V2_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V2_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V4",
          "ParameterKey": "frequency_hfr_cross_re_V1V2_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_re_V1V2_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V2_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_GND",
          "ParameterKey": "frequency_hfr_cross_re_V1V2_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V2_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V2_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_re_V1V3_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V3_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V3V4",
          "ParameterKey": "frequency_hfr_cross_re_V1V3_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_re_V1V3_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V3_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V3V2",
          "ParameterKey": "frequency_hfr_cross_re_V1V3_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_re_V1V3_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V3_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V1V4",
          "ParameterKey": "frequency_hfr_cross_re_V1V3_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_re_V1V3_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V3_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_SCM",
          "ParameterKey": "frequency_hfr_cross_re_V1V3_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_re_V1V3_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V3_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V2",
          "ParameterKey": "frequency_hfr_cross_re_V1V3_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_re_V1V3_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V3_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V4",
          "ParameterKey": "frequency_hfr_cross_re_V1V3_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_re_V1V3_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1V3_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_GND",
          "ParameterKey": "frequency_hfr_cross_re_V1V3_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1V3_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1V3_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_re_V2V4_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V2V4_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V3V4",
          "ParameterKey": "frequency_hfr_cross_re_V2V4_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_re_V2V4_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V2V4_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V3V2",
          "ParameterKey": "frequency_hfr_cross_re_V2V4_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_re_V2V4_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V2V4_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V1V4",
          "ParameterKey": "frequency_hfr_cross_re_V2V4_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_re_V2V4_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V2V4_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_SCM",
          "ParameterKey": "frequency_hfr_cross_re_V2V4_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_re_V2V4_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V2V4_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V2",
          "ParameterKey": "frequency_hfr_cross_re_V2V4_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_re_V2V4_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V2V4_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V4",
          "ParameterKey": "frequency_hfr_cross_re_V2V4_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_re_V2V4_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V2V4_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_GND",
          "ParameterKey": "frequency_hfr_cross_re_V2V4_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V2V4_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V2V4_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_re_SCM_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re SCM_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V3V4",
          "ParameterKey": "frequency_hfr_cross_re_SCM_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_re_SCM_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re SCM_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V3V2",
          "ParameterKey": "frequency_hfr_cross_re_SCM_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_re_SCM_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re SCM_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V1V4",
          "ParameterKey": "frequency_hfr_cross_re_SCM_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_re_SCM_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re SCM_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_SCM",
          "ParameterKey": "frequency_hfr_cross_re_SCM_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_re_SCM_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re SCM_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V2",
          "ParameterKey": "frequency_hfr_cross_re_SCM_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_re_SCM_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re SCM_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V4",
          "ParameterKey": "frequency_hfr_cross_re_SCM_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_re_SCM_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re SCM_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_GND",
          "ParameterKey": "frequency_hfr_cross_re_SCM_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_SCM_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re SCM_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_re_V1_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V3V4",
          "ParameterKey": "frequency_hfr_cross_re_V1_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_re_V1_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V3V2",
          "ParameterKey": "frequency_hfr_cross_re_V1_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_re_V1_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V1V4",
          "ParameterKey": "frequency_hfr_cross_re_V1_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_re_V1_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_SCM",
          "ParameterKey": "frequency_hfr_cross_re_V1_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_re_V1_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V2",
          "ParameterKey": "frequency_hfr_cross_re_V1_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_re_V1_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V4",
          "ParameterKey": "frequency_hfr_cross_re_V1_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_re_V1_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V1_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_GND",
          "ParameterKey": "frequency_hfr_cross_re_V1_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V1_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V1_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_re_V3_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V3_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V3V4",
          "ParameterKey": "frequency_hfr_cross_re_V3_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_re_V3_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V3_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V3V2",
          "ParameterKey": "frequency_hfr_cross_re_V3_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_re_V3_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V3_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V1V4",
          "ParameterKey": "frequency_hfr_cross_re_V3_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_re_V3_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V3_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_SCM",
          "ParameterKey": "frequency_hfr_cross_re_V3_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_re_V3_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V3_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V2",
          "ParameterKey": "frequency_hfr_cross_re_V3_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_re_V3_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V3_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V4",
          "ParameterKey": "frequency_hfr_cross_re_V3_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_re_V3_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re V3_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_GND",
          "ParameterKey": "frequency_hfr_cross_re_V3_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_V3_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re V3_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_cross_re_GND_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re GND_V3V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V3V4",
          "ParameterKey": "frequency_hfr_cross_re_GND_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_cross_re_GND_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re GND_V3V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V3V2",
          "ParameterKey": "frequency_hfr_cross_re_GND_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_cross_re_GND_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re GND_V1V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V1V4",
          "ParameterKey": "frequency_hfr_cross_re_GND_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_cross_re_GND_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re GND_SCM PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_SCM",
          "ParameterKey": "frequency_hfr_cross_re_GND_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_cross_re_GND_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re GND_V2 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V2",
          "ParameterKey": "frequency_hfr_cross_re_GND_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_cross_re_GND_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re GND_V4 PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V4",
          "ParameterKey": "frequency_hfr_cross_re_GND_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_cross_re_GND_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "V^2/Hz",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR cross_re GND_GND PSD",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-1.0e+30",
          "ValidMax": "1.0e+30",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_GND",
          "ParameterKey": "frequency_hfr_cross_re_GND_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Real Part, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_CROSS_RE_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_cross_re_GND_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Real Part, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR cross_re GND_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_coher_V1V2_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V2_V3V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V3V4",
          "ParameterKey": "frequency_hfr_coher_V1V2_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_coher_V1V2_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V2_V3V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V3V2",
          "ParameterKey": "frequency_hfr_coher_V1V2_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_coher_V1V2_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V2_V1V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V1V4",
          "ParameterKey": "frequency_hfr_coher_V1V2_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_coher_V1V2_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V2_SCM Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_SCM",
          "ParameterKey": "frequency_hfr_coher_V1V2_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_coher_V1V2_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V2_V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V2",
          "ParameterKey": "frequency_hfr_coher_V1V2_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_coher_V1V2_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V2_V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V4",
          "ParameterKey": "frequency_hfr_coher_V1V2_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_coher_V1V2_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V2_GND Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_GND",
          "ParameterKey": "frequency_hfr_coher_V1V2_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V2_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V2_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_coher_V1V3_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V3_V3V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V3V4",
          "ParameterKey": "frequency_hfr_coher_V1V3_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_coher_V1V3_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V3_V3V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V3V2",
          "ParameterKey": "frequency_hfr_coher_V1V3_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_coher_V1V3_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V3_V1V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V1V4",
          "ParameterKey": "frequency_hfr_coher_V1V3_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_coher_V1V3_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V3_SCM Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_SCM",
          "ParameterKey": "frequency_hfr_coher_V1V3_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_coher_V1V3_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V3_V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V2",
          "ParameterKey": "frequency_hfr_coher_V1V3_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_coher_V1V3_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V3_V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V4",
          "ParameterKey": "frequency_hfr_coher_V1V3_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_coher_V1V3_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1V3_GND Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_GND",
          "ParameterKey": "frequency_hfr_coher_V1V3_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1V3_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1V3_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_coher_V2V4_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V2V4_V3V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V3V4",
          "ParameterKey": "frequency_hfr_coher_V2V4_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_coher_V2V4_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V2V4_V3V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V3V2",
          "ParameterKey": "frequency_hfr_coher_V2V4_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_coher_V2V4_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V2V4_V1V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V1V4",
          "ParameterKey": "frequency_hfr_coher_V2V4_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_coher_V2V4_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V2V4_SCM Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_SCM",
          "ParameterKey": "frequency_hfr_coher_V2V4_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_coher_V2V4_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V2V4_V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V2",
          "ParameterKey": "frequency_hfr_coher_V2V4_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_coher_V2V4_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V2V4_V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V4",
          "ParameterKey": "frequency_hfr_coher_V2V4_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_coher_V2V4_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V2V4_GND Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_GND",
          "ParameterKey": "frequency_hfr_coher_V2V4_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V2V4_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V2V4_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_coher_SCM_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher SCM_V3V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V3V4",
          "ParameterKey": "frequency_hfr_coher_SCM_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_coher_SCM_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher SCM_V3V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V3V2",
          "ParameterKey": "frequency_hfr_coher_SCM_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_coher_SCM_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher SCM_V1V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V1V4",
          "ParameterKey": "frequency_hfr_coher_SCM_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_coher_SCM_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher SCM_SCM Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_SCM",
          "ParameterKey": "frequency_hfr_coher_SCM_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_coher_SCM_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher SCM_V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V2",
          "ParameterKey": "frequency_hfr_coher_SCM_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_coher_SCM_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher SCM_V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V4",
          "ParameterKey": "frequency_hfr_coher_SCM_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_coher_SCM_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher SCM_GND Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_GND",
          "ParameterKey": "frequency_hfr_coher_SCM_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_SCM_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher SCM_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_coher_V1_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1_V3V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V3V4",
          "ParameterKey": "frequency_hfr_coher_V1_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_coher_V1_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1_V3V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V3V2",
          "ParameterKey": "frequency_hfr_coher_V1_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_coher_V1_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1_V1V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V1V4",
          "ParameterKey": "frequency_hfr_coher_V1_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_coher_V1_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1_SCM Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_SCM",
          "ParameterKey": "frequency_hfr_coher_V1_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_coher_V1_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1_V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V2",
          "ParameterKey": "frequency_hfr_coher_V1_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_coher_V1_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1_V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V4",
          "ParameterKey": "frequency_hfr_coher_V1_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_coher_V1_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V1_GND Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_GND",
          "ParameterKey": "frequency_hfr_coher_V1_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V1_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V1_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_coher_V3_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V3_V3V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V3V4",
          "ParameterKey": "frequency_hfr_coher_V3_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_coher_V3_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V3_V3V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V3V2",
          "ParameterKey": "frequency_hfr_coher_V3_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_coher_V3_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V3_V1V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V1V4",
          "ParameterKey": "frequency_hfr_coher_V3_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_coher_V3_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V3_SCM Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_SCM",
          "ParameterKey": "frequency_hfr_coher_V3_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_coher_V3_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V3_V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V2",
          "ParameterKey": "frequency_hfr_coher_V3_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_coher_V3_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V3_V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V4",
          "ParameterKey": "frequency_hfr_coher_V3_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_coher_V3_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher V3_GND Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_GND",
          "ParameterKey": "frequency_hfr_coher_V3_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_V3_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher V3_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_coher_GND_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher GND_V3V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V3V4",
          "ParameterKey": "frequency_hfr_coher_GND_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_coher_GND_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher GND_V3V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V3V2",
          "ParameterKey": "frequency_hfr_coher_GND_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_coher_GND_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher GND_V1V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V1V4",
          "ParameterKey": "frequency_hfr_coher_GND_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_coher_GND_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher GND_SCM Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_SCM",
          "ParameterKey": "frequency_hfr_coher_GND_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_coher_GND_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher GND_V2 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V2",
          "ParameterKey": "frequency_hfr_coher_GND_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_coher_GND_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher GND_V4 Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V4",
          "ParameterKey": "frequency_hfr_coher_GND_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_coher_GND_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR coher GND_GND Coherence",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "1.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "CrossSpectrum",
              "Magnitude"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_GND",
          "ParameterKey": "frequency_hfr_coher_GND_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Coherence, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_COHER_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_coher_GND_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Coherence, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR coher GND_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_phase_V1V2_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V2_V3V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V3V4",
          "ParameterKey": "frequency_hfr_phase_V1V2_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_phase_V1V2_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V2_V3V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V3V2",
          "ParameterKey": "frequency_hfr_phase_V1V2_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_phase_V1V2_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V2_V1V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V1V4",
          "ParameterKey": "frequency_hfr_phase_V1V2_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_phase_V1V2_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V2_SCM Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_SCM",
          "ParameterKey": "frequency_hfr_phase_V1V2_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_phase_V1V2_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V2_V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V2",
          "ParameterKey": "frequency_hfr_phase_V1V2_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_phase_V1V2_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V2_V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V4",
          "ParameterKey": "frequency_hfr_phase_V1V2_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_phase_V1V2_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V2_GND Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_GND",
          "ParameterKey": "frequency_hfr_phase_V1V2_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V2, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V2_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V2_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V2 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V2_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_phase_V1V3_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V3_V3V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V3V4",
          "ParameterKey": "frequency_hfr_phase_V1V3_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_phase_V1V3_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V3_V3V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V3V2",
          "ParameterKey": "frequency_hfr_phase_V1V3_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_phase_V1V3_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V3_V1V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V1V4",
          "ParameterKey": "frequency_hfr_phase_V1V3_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_phase_V1V3_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V3_SCM Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_SCM",
          "ParameterKey": "frequency_hfr_phase_V1V3_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_phase_V1V3_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V3_V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V2",
          "ParameterKey": "frequency_hfr_phase_V1V3_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_phase_V1V3_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V3_V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V4",
          "ParameterKey": "frequency_hfr_phase_V1V3_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_phase_V1V3_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1V3_GND Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_GND",
          "ParameterKey": "frequency_hfr_phase_V1V3_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1-V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1V3_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1-V3 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1V3_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_phase_V2V4_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V2V4_V3V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V3V4",
          "ParameterKey": "frequency_hfr_phase_V2V4_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_phase_V2V4_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V2V4_V3V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V3V2",
          "ParameterKey": "frequency_hfr_phase_V2V4_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_phase_V2V4_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V2V4_V1V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V1V4",
          "ParameterKey": "frequency_hfr_phase_V2V4_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_phase_V2V4_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V2V4_SCM Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_SCM",
          "ParameterKey": "frequency_hfr_phase_V2V4_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_phase_V2V4_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V2V4_V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V2",
          "ParameterKey": "frequency_hfr_phase_V2V4_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_phase_V2V4_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V2V4_V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V4",
          "ParameterKey": "frequency_hfr_phase_V2V4_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_phase_V2V4_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V2V4_GND Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_GND",
          "ParameterKey": "frequency_hfr_phase_V2V4_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V2-V4, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V2V4_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V2V4_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V2-V4 dipole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V2V4_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_phase_SCM_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase SCM_V3V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V3V4",
          "ParameterKey": "frequency_hfr_phase_SCM_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_phase_SCM_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase SCM_V3V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V3V2",
          "ParameterKey": "frequency_hfr_phase_SCM_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_phase_SCM_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase SCM_V1V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V1V4",
          "ParameterKey": "frequency_hfr_phase_SCM_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_phase_SCM_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase SCM_SCM Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_SCM",
          "ParameterKey": "frequency_hfr_phase_SCM_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_phase_SCM_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase SCM_V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V2",
          "ParameterKey": "frequency_hfr_phase_SCM_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_phase_SCM_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase SCM_V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V4",
          "ParameterKey": "frequency_hfr_phase_SCM_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_phase_SCM_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase SCM_GND Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_GND",
          "ParameterKey": "frequency_hfr_phase_SCM_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: SCM, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_SCM_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_SCM_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Search Coil Magnetometer, SCM, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase SCM_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_phase_V1_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1_V3V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V3V4",
          "ParameterKey": "frequency_hfr_phase_V1_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_phase_V1_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1_V3V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V3V2",
          "ParameterKey": "frequency_hfr_phase_V1_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_phase_V1_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1_V1V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V1V4",
          "ParameterKey": "frequency_hfr_phase_V1_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_phase_V1_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1_SCM Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_SCM",
          "ParameterKey": "frequency_hfr_phase_V1_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_phase_V1_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1_V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V2",
          "ParameterKey": "frequency_hfr_phase_V1_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_phase_V1_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1_V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V4",
          "ParameterKey": "frequency_hfr_phase_V1_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_phase_V1_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V1_GND Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_GND",
          "ParameterKey": "frequency_hfr_phase_V1_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V1, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V1_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V1_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V1 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V1_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_phase_V3_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V3_V3V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V3V4",
          "ParameterKey": "frequency_hfr_phase_V3_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_phase_V3_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V3_V3V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V3V2",
          "ParameterKey": "frequency_hfr_phase_V3_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_phase_V3_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V3_V1V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V1V4",
          "ParameterKey": "frequency_hfr_phase_V3_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_phase_V3_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V3_SCM Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_SCM",
          "ParameterKey": "frequency_hfr_phase_V3_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_phase_V3_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V3_V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V2",
          "ParameterKey": "frequency_hfr_phase_V3_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_phase_V3_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V3_V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V4",
          "ParameterKey": "frequency_hfr_phase_V3_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_phase_V3_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase V3_GND Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_GND",
          "ParameterKey": "frequency_hfr_phase_V3_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: V3, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_V3_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_V3_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: V3 monopole antenna signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase V3_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V3-V4",
          "ParameterKey": "epoch_hfr_phase_GND_V3V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V3V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase GND_V3V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V3V4",
          "ParameterKey": "frequency_hfr_phase_GND_V3V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V3V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V3V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V3V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V3V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V3-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V3V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V3V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V3-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V3V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V3-V2",
          "ParameterKey": "epoch_hfr_phase_GND_V3V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V3V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase GND_V3V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V3V2",
          "ParameterKey": "frequency_hfr_phase_GND_V3V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V3V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V3V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V3V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V3V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V3-V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V3V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V3V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V3-V2 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V3V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V1-V4",
          "ParameterKey": "epoch_hfr_phase_GND_V1V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V1V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase GND_V1V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V1V4",
          "ParameterKey": "frequency_hfr_phase_GND_V1V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V1V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V1V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V1V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V1V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V1-V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V1V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V1V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V1-V4 dipole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V1V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: SCM",
          "ParameterKey": "epoch_hfr_phase_GND_SCM",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_SCM",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase GND_SCM Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_SCM",
          "ParameterKey": "frequency_hfr_phase_GND_SCM",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_SCM_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_SCM gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_SCM_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_SCM nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: SCM",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_SCM",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_SCM_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: Search Coil Magnetometer, SCM, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_SCM hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V2",
          "ParameterKey": "epoch_hfr_phase_GND_V2",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V2",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase GND_V2 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V2",
          "ParameterKey": "frequency_hfr_phase_GND_V2",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V2_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V2 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V2_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V2 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V2",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V2",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V2_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V2 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V2 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V4",
          "ParameterKey": "epoch_hfr_phase_GND_V4",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V4",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase GND_V4 Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V4",
          "ParameterKey": "frequency_hfr_phase_GND_V4",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V4_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V4 gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V4_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V4 nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: V4",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_V4",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_V4_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: V4 monopole antenna signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_V4 hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: GND",
          "ParameterKey": "epoch_hfr_phase_GND_GND",
          "Description": "Epoch Time, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_GND",
          "Description": "High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "°",
          "UnitsConversion": "0.0174532925>rad",
          "RenderingHints": {
            "DisplayType": "Spectrogram",
            "AxisLabel": "HFR phase GND_GND Phase",
            "ValueFormat": "E12.2",
            "ScaleType": "LinearScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "-180.0",
          "ValidMax": "180.0",
          "FillValue": "-1.0e+31",
          "Wave": {
            "WaveType": "PlasmaWaves",
            "Qualifier": [
              "Array",
              "PhaseAngle"
            ],
            "WaveQuantity": "Intensity"
          }
        },
        {
          "Name": "Frequencies, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_GND",
          "ParameterKey": "frequency_hfr_phase_GND_GND",
          "Description": "Frequencies, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "Units": "Hz",
          "RenderingHints": {
            "AxisLabel": "Frequency",
            "ValueFormat": "E12.2",
            "ScaleType": "LogScale"
          },
          "Structure": {
            "Size": "64"
          },
          "ValidMin": "0.0",
          "ValidMax": "2.0e+07",
          "FillValue": "-1.0e+31",
          "Support": {
            "Qualifier": "Array",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Gain Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_GND_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_GND gain",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_GND_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_GND nsum",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "Over Range Flag, HFR, Cross Spectra, Phase, Ch. 0: GND, Ch. 1: GND",
          "Set": "Time Series defined by using: EPOCH_HFR_PHASE_GND_GND",
          "ParameterKey": "psp_fld_l2_rfs_hfr_phase_GND_GND_hl",
          "Description": "Over Range Flag, High Frequency Receiver, HFR, Cross Spectra, Phase, Channel 0: Ground, GND, signal, Channel 1: Ground, GND, signal",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR phase GND_GND hl",
            "ValueFormat": "I6",
            "ScaleType": "LinearScale"
          },
          "ValidMin": "0",
          "ValidMax": "3",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, HFR, all Auto and Cross Spectra",
          "ParameterKey": "epoch_hfr",
          "Description": "Epoch Time, High Frequency Receiver, HFR, all Auto and Cross Spectra",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2049-12-31T23:59:59.999999999",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "HFR, Average Mode Enable Flag, all Auto and Cross Spectra",
          "Set": "Time Series defined by using: EPOCH_HFR",
          "ParameterKey": "psp_fld_l2_rfs_hfr_averages",
          "Description": "High Frequency Receiver, HFR, Average Mode Enable Flag, all Auto and Cross Spectra",
          "Caveats": "Average mode enable flag for all HFR spectra. A value of 1 indicates that average mode is enabled, and a value of 0 indicates that average mode is disabled.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR averages",
            "ValueFormat": "I6"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Peak Mode Enable Flag, all Auto and Cross Spectra",
          "Set": "Time Series defined by using: EPOCH_HFR",
          "ParameterKey": "psp_fld_l2_rfs_hfr_peaks",
          "Description": "High Frequency Receiver, HFR, Peak Mode Enable Flag, all Auto and Cross Spectra",
          "Caveats": "Peak mode enable flag for all HFR spectra. A value of 1 indicates that peak mode is enabled, and a value of 0 indicates that peak mode is disabled.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR peaks",
            "ValueFormat": "I6"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Channel 0 Source, all Auto and Cross Spectra, String Variable",
          "Set": "Time Series defined by using: EPOCH_HFR",
          "ParameterKey": "psp_fld_l2_rfs_hfr_ch0",
          "Description": "High Frequency Receiver, HFR, Channel 0 Source, all Auto and Cross Spectra, String Variable",
          "Caveats": "Source for HFR Channel 0 data. 0: V1V2, 1: V1V3, 2: V2V4, 3: SCM, 4: V1, 5: V3, 6: GND, 7: GND",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR ch0",
            "ValueFormat": "I6"
          },
          "ValidMin": "0",
          "ValidMax": "7",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Channel 1 Source, all Auto and Cross Spectra",
          "Set": "Time Series defined by using: EPOCH_HFR",
          "ParameterKey": "psp_fld_l2_rfs_hfr_ch1",
          "Description": "High Frequency Receiver, HFR, Channel 1 Source, all Auto and Cross Spectra",
          "Caveats": "Source for HFR Channel 1 data. 0: V3V4, 1: V3V2, 2: V1V4, 3: SCM, 4: V2, 5: V4, 6: GND, 7: GND",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR ch1",
            "ValueFormat": "I6"
          },
          "ValidMin": "0",
          "ValidMax": "7",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Number of Spectra summed, all Auto and Cross Spectra",
          "Set": "Time Series defined by using: EPOCH_HFR",
          "ParameterKey": "psp_fld_l2_rfs_hfr_nsum",
          "Description": "High Frequency Receiver, HFR, Number of Spectra summed, all Auto and Cross Spectra",
          "Caveats": "Number of summed individual spectra for the High Frequency Receiver, HFR, auto and cross reduced spectra",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR nsum",
            "ValueFormat": "I6"
          },
          "ValidMin": "0",
          "ValidMax": "128",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "Other"
          }
        },
        {
          "Name": "HFR, Gain Flag, all Auto and Cross Spectra",
          "Set": "Time Series defined by using: EPOCH_HFR",
          "ParameterKey": "psp_fld_l2_rfs_hfr_gain",
          "Description": "Gain Flag, High Frequency Receiver, HFR, all Auto and Cross Spectra",
          "Caveats": "Gain flag for HFR auto and cross reduced spectra. 0: Low Gain, 1: High Gain",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR gain",
            "ValueFormat": "I6"
          },
          "ValidMin": "0",
          "ValidMax": "1",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "HFR, Over Range Flag, all Auto and Cross Spectra",
          "Set": "Time Series defined by using: EPOCH_HFR",
          "ParameterKey": "psp_fld_l2_rfs_hfr_hl",
          "Description": "High Frequency Receiver, HFR, Over Range Flag, all Auto and Cross Spectra",
          "Caveats": "Overrange flag for XFR auto and cross reduced spectra. The flag indicates whether or not at least one out of range condition occurred in at least one input waveform collected during the LFR or HFR accumulation interval (see Ref. [3]). 0: No overrange conditions, 1: Overrange in Low Gain but not in High Gain, 2: Overrange in High Gain but not in Low Gain, 3: Overrange in Low Gain and High Gain.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "HFR hl",
            "ValueFormat": "I6"
          },
          "ValidMin": "0",
          "ValidMax": "2",
          "FillValue": "-32768",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        },
        {
          "Name": "Epoch Time, FIELDS, HFR, Instrument Data Quality Flag",
          "ParameterKey": "epoch_quality_flags",
          "Description": "Epoch Time, FIELDS, High Frequency Receiver, HFR, Instrument Data Quality Flag",
          "Caveats": "This Parameter exhibits an increasing Monotonic Progression",
          "Cadence": "PT7S",
          "Units": "ns",
          "UnitsConversion": "1.0e-9>s",
          "RenderingHints": {
            "AxisLabel": "epoch",
            "ValueFormat": "I22",
            "ScaleMin": "6.3708660219904e+13",
            "ScaleMax": "6.3708746619904e+13"
          },
          "ValidMin": "2010-01-01T00:00:00.000000000",
          "ValidMax": "2050-01-01T00:00:00.000000000",
          "FillValue": "9999-12-31T23:59:59.999999999",
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "FIELDS Data Quality Flags",
          "Set": "Time Series defined by using: EPOCH_QUALITY_FLAGS",
          "ParameterKey": "psp_fld_l2_quality_flags",
          "Description": "FIELDS Instrument Suite Data Quality Flags",
          "Caveats": "FIELDS quality flags: These flags are bitwise variables, meaning that multiple flags can be set simultaneously for a single time by adding flag values. Current flagged values are:\n\n* 1: FIELDS Antenna Bias Sweep\n* 2: PSP Thruster Firing\n* 4: SCM Calibration\n* 8: PSP Rotations for MAG Calibration, MAG Rolls\n* 16: FIELDS MAG Calibration Sequence\n* 32: SWEAP SPC in Electron Mode\n* 64: PSP Solar Limb Sensor, SLS, Test\n* 128: PSP Spacecraft is off Umbra Pointing, Heat Shield not pointed Sunward\n* 256: High Frequency Noise affecting RFS and TDS Receivers\n* 512: Antennas driven towards the FIELDS Power Supply Rails\n\nA value of zero corresponds to no set flags. Not all flags are relevant to all FIELDS data products, refer to notes in the CDF metadata and on the FIELDS Satellite Operations Center, SOC, website for information on how the various flags impact FIELDS data. For more information on the quality flags describing high frequency noise and antennas driven to the rails, see release notes for PSP/FIELDS releases 8 and 9. Additional flagged items may be added in the future.",
          "Cadence": "PT7S",
          "RenderingHints": {
            "AxisLabel": "flag",
            "ValueFormat": "I10"
          },
          "ValidMin": "0",
          "ValidMax": "1023",
          "FillValue": "4294967295",
          "Support": {
            "Qualifier": "Scalar",
            "SupportQuantity": "InstrumentMode"
          }
        }
      ]
    }
  }
}