<?xml version="1.0"?>
<Spase xmlns="http://www.spase-group.org/data/schema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.spase-group.org/data/schema http://www.spase-group.org/data/schema/spase-2_3_1.xsd">
  <Version>2.3.1</Version>
  <NumericalData>
    <ResourceID>spase://NOAA/NumericalData/GOES/14/EPS/MAGED/19ME4/PT16S</ResourceID>
    <ResourceHeader>
      <ResourceName>GOES 14 Magnetospheric Electron Detector (MAGED) data with energy from 200 to 350 keV at 16 s Time Resolution in Spacecraft Coordinates</ResourceName>
      <AlternateName>GOES 14 MAGED 19ME4 data</AlternateName>
      <ReleaseDate>2020-05-04T13:45:15Z</ReleaseDate>
      <Description>The GOES 14 Magnetospheric Electron Detector (MAGED) are essentially the same as the Energetic Particle Sensor (EPS) on GOES 8-12. For more information, please see Onsager et al. 1996, Operational uses of the GOES energetic particle detectors, in GOES 8 and Beyond, Proc. SPIE, Vol. 2812, edited by E. R. Washwell, pp. 281-290, Bellingham, WA. These data file contain mainly information on the electron count rates and fluxes from 200 to 350 keV. Data files contain long descriptive header.</Description>
      <Acknowledgement>NASA Office of Space Science Applications (United States), NOAA National Environmental Satellite Service (United States), Terry G. Onsager</Acknowledgement>
      <Contact>
        <PersonID>spase://SMWG/Person/Terry.Onsager</PersonID>
        <Role>PrincipalInvestigator</Role>
      </Contact>
      <Contact>
        <PersonID>spase://SMWG/Person/James.M.Weygand</PersonID>
        <Role>MetadataContact</Role>
      </Contact>
      <InformationURL>
        <Name>GOES N, O, and P Brochure</Name>
        <URL>https://www.nasa.gov/pdf/112855main_GOESNOPWeb1.pdf</URL>
        <Description>Information about the magnetometers onboard GOES 14</Description>
        <Language>en</Language>
      </InformationURL>
      <PriorID>spase://VMO/NumericalData/GOES/14/EPEAD/meged_19me4_PT16S</PriorID>
      <PriorID>spase://VMO/NumericalData/GOES/14/EPS/meged_19me4_PT16S</PriorID>
      <PriorID>spase://VSPO/NumericalData/GOES/14/EPS/MAGED/19ME4/PT16S</PriorID>
    </ResourceHeader>
    <AccessInformation>
      <RepositoryID>spase://SMWG/Repository/NOAA/SEC</RepositoryID>
      <Availability>Online</Availability>
      <AccessRights>Open</AccessRights>
      <AccessURL>
        <Name>Direct access to the GOES 14 Magnetospheric Electron Detector (MAGED) data</Name>
        <URL>https://satdat.ngdc.noaa.gov/sem/goes/data/full/</URL>
        <Description>Direct link to the GOES 14 Magnetospheric Electron Detector (MAGED) data in CSV format as well as the energetic particle data from other GOES spacecraft. The data are sorted by year, month, spacecraft, and file type. The file names indicates the data type, spacecraft number, year, month, and resolution. For example, g14_maged_19me3_4s_20110617_20110617.csv, indicates GOES 14 magnetometer data at 4 s time resolution for 2011-06-17.</Description>
      </AccessURL>
      <Format>Text.ASCII</Format>
      <Encoding>None</Encoding>
      <Acknowledgement>NASA, NOAA, Terry G. Onsager</Acknowledgement>
    </AccessInformation>
    <ProcessingLevel>Calibrated</ProcessingLevel>
    <ProviderResourceName>NOAA GOES 14 MAGED</ProviderResourceName>
    <ProviderProcessingLevel>Level-2</ProviderProcessingLevel>
    <InstrumentID>spase://SMWG/Instrument/GOES/14/EPS</InstrumentID>
    <MeasurementType>EnergeticParticles</MeasurementType>
    <TemporalDescription>
      <TimeSpan>
        <StartDate>2012-10-01T00:00:00</StartDate>
        <StopDate>2012-11-24T23:59:00</StopDate>
        <Note>Time format in data files is year-month-day hour:minute:seconds. Data file may fill out the first month and last month with flags.</Note>
      </TimeSpan>
      <Cadence>PT16S</Cadence>
    </TemporalDescription>
    <Caveats>Flags=-99999.0</Caveats>
    <Keyword>16 s</Keyword>
    <Keyword>geosynchronous</Keyword>
    <Keyword>GOES</Keyword>
    <Keyword>Magnetospheric Electron Detector</Keyword>
    <Parameter>
      <Name>Seconds of the Month</Name>
      <ParameterKey>Time</ParameterKey>
      <Description>Time format in data files is year-month-day hour:minute:seconds.</Description>
      <Support>
        <SupportQuantity>Temporal</SupportQuantity>
      </Support>
    </Parameter>
    <Parameter>
      <Name>Quality flag for electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_1ME4_QUAL_FLAG</ParameterKey>
      <Description>Quality flag non-zero value indicates data quality issue in telescope 1</Description>
      <ValidMin>0</ValidMin>
      <ValidMax>4294967295</ValidMax>
      <FillValue>99999</FillValue>
      <Support>
        <SupportQuantity>Other</SupportQuantity>
      </Support>
    </Parameter>
    <Parameter>
      <Name>Average Count of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_1ME4_COUNT</ParameterKey>
      <Description>Average total counts of electrons with energy from 200 to 350 keV measured by telescope 1</Description>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e6</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>Counts</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Count rate of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_1ME4_COUNT_RATE</ParameterKey>
      <Description>Average counts/s of electrons with energy from 200 to 350 keV measured by telescope 1</Description>
      <Units>s^-1</Units>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e8</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>CountRate</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Quality flag for electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_2ME4_QUAL_FLAG</ParameterKey>
      <Description>Quality flag non-zero value indicates data quality issue in telescope 2</Description>
      <ValidMin>0</ValidMin>
      <ValidMax>4294967295</ValidMax>
      <FillValue>99999</FillValue>
      <Support>
        <SupportQuantity>Other</SupportQuantity>
      </Support>
    </Parameter>
    <Parameter>
      <Name>Average Count of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_2ME4_COUNT</ParameterKey>
      <Description>Average total counts of electrons with energy from 200 to 350 keV measured by telescope 2</Description>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e6</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>Counts</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Count rate of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_2ME4_COUNT_RATE</ParameterKey>
      <Description>Average counts/s of electrons with energy from 200 to 350 keV measured by telescope 2</Description>
      <Units>s^-1</Units>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e8</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>CountRate</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Quality flag for electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_3ME4_QUAL_FLAG</ParameterKey>
      <Description>Quality flag non-zero value indicates data quality issue in telescope 3</Description>
      <ValidMin>0</ValidMin>
      <ValidMax>4294967295</ValidMax>
      <FillValue>99999</FillValue>
      <Support>
        <SupportQuantity>Other</SupportQuantity>
      </Support>
    </Parameter>
    <Parameter>
      <Name>Average Count of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_3ME4_COUNT</ParameterKey>
      <Description>Average total counts of electrons with energy from 200 to 350 keV measured by telescope 3</Description>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e6</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>Counts</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Count rate of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_3ME4_COUNT_RATE</ParameterKey>
      <Description>Average counts/s of electrons with energy from 200 to 350 keV measured by telescope 3</Description>
      <Units>s^-1</Units>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e8</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>CountRate</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Quality flag for electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_4ME4_QUAL_FLAG</ParameterKey>
      <Description>Quality flag non-zero value indicates data quality issue in telescope 4</Description>
      <ValidMin>0</ValidMin>
      <ValidMax>4294967295</ValidMax>
      <FillValue>99999</FillValue>
      <Support>
        <SupportQuantity>Other</SupportQuantity>
      </Support>
    </Parameter>
    <Parameter>
      <Name>Average Count of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_4ME4_COUNT</ParameterKey>
      <Description>Average total counts of electrons with energy from 200 to 350 keV measured by telescope 4</Description>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e6</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>Counts</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Count rate of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_4ME4_COUNT_RATE</ParameterKey>
      <Description>Average counts/s of electrons with energy from 200 to 350 keV measured by telescope 4</Description>
      <Units>s^-1</Units>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e8</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>CountRate</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Quality flag for electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_5ME4_QUAL_FLAG</ParameterKey>
      <Description>Quality flag non-zero value indicates data quality issue in telescope 5.</Description>
      <ValidMin>0</ValidMin>
      <ValidMax>4294967295</ValidMax>
      <FillValue>99999</FillValue>
      <Support>
        <SupportQuantity>Other</SupportQuantity>
      </Support>
    </Parameter>
    <Parameter>
      <Name>Average Count of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_5ME4_COUNT</ParameterKey>
      <Description>Average total counts of electrons with energy from 200 to 350 keV measured by telescope 5.</Description>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e6</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>Counts</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Count rate of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_5ME4_COUNT_RATE</ParameterKey>
      <Description>Average counts/s of electrons with energy from 200 to 350 keV measured by telescope 5.</Description>
      <Units>s^-1</Units>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e8</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>CountRate</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Quality flag for electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_6ME4_QUAL_FLAG</ParameterKey>
      <Description>Quality flag non-zero value indicates data quality issue in telescope 6.</Description>
      <ValidMin>0</ValidMin>
      <ValidMax>4294967295</ValidMax>
      <FillValue>99999</FillValue>
      <Support>
        <SupportQuantity>Other</SupportQuantity>
      </Support>
    </Parameter>
    <Parameter>
      <Name>Average Count of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_6ME4_COUNT</ParameterKey>
      <Description>Average total counts of electrons with energy from 200 to 350 keV measured by telescope 6.</Description>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e6</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>Counts</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Count rate of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_6ME4_COUNT_RATE</ParameterKey>
      <Description>Average counts/s of electrons with energy from 200 to 350 keV measured by telescope 6.</Description>
      <Units>s^-1</Units>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e8</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>CountRate</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Quality flag for electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_7ME4_QUAL_FLAG</ParameterKey>
      <Description>Quality flag non-zero value indicates data quality issue in telescope 7.</Description>
      <ValidMin>0</ValidMin>
      <ValidMax>4294967295</ValidMax>
      <FillValue>99999</FillValue>
      <Support>
        <SupportQuantity>Other</SupportQuantity>
      </Support>
    </Parameter>
    <Parameter>
      <Name>Average Count of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_7ME4_COUNT</ParameterKey>
      <Description>Average total counts of electrons with energy from 200 to 350 keV measured by telescope 7.</Description>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e6</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>Counts</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Count rate of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_7ME4_COUNT_RATE</ParameterKey>
      <Description>Average counts/s of electrons with energy from 200 to 350 keV measured by telescope 7.</Description>
      <Units>s^-1</Units>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e8</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>CountRate</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Quality flag for electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_8ME4_QUAL_FLAG</ParameterKey>
      <Description>Quality flag non-zero value indicates data quality issue in telescope 8.</Description>
      <ValidMin>0</ValidMin>
      <ValidMax>4294967295</ValidMax>
      <FillValue>99999</FillValue>
      <Support>
        <SupportQuantity>Other</SupportQuantity>
      </Support>
    </Parameter>
    <Parameter>
      <Name>Average Count of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_8ME4_COUNT</ParameterKey>
      <Description>Average total counts of electrons with energy from 200 to 350 keV measured by telescope 8.</Description>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e6</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>Counts</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Count rate of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_8ME4_COUNT_RATE</ParameterKey>
      <Description>Average counts/s of electrons with energy from 200 to 350 keV measured by telescope 8.</Description>
      <Units>s^-1</Units>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e8</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>CountRate</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Quality flag for electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_9ME4_QUAL_FLAG</ParameterKey>
      <Description>Quality flag non-zero value indicates data quality issue in telescope 9.</Description>
      <ValidMin>0</ValidMin>
      <ValidMax>4294967295</ValidMax>
      <FillValue>99999</FillValue>
      <Support>
        <SupportQuantity>Other</SupportQuantity>
      </Support>
    </Parameter>
    <Parameter>
      <Name>Average Count of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_9ME4_COUNT</ParameterKey>
      <Description>Average total counts of electrons with energy from 200 to 350 keV measured by telescope 9.</Description>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e6</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>Counts</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
    <Parameter>
      <Name>Count rate of electrons with energy from 200 to 350 keV</Name>
      <ParameterKey>M_9ME4_COUNT_RATE</ParameterKey>
      <Description>Average counts/s of electrons with energy from 200 to 350 keV measured by telescope 9.</Description>
      <Units>s^-1</Units>
      <ValidMin>0.0</ValidMin>
      <ValidMax>1.0e8</ValidMax>
      <FillValue>-99999</FillValue>
      <Particle>
        <ParticleType>Electron</ParticleType>
        <ParticleQuantity>CountRate</ParticleQuantity>
        <EnergyRange>
          <Low>200</Low>
          <High>350</High>
          <Units>keV</Units>
        </EnergyRange>
      </Particle>
    </Parameter>
  </NumericalData>
</Spase>
