  <Instrument>
    <ResourceID>spase://SMWG/Instrument/FAST/EFLP</ResourceID>
    <ResourceHeader>
      <ResourceName>Electric Field and Langmuir Probe Experiment</ResourceName>
      <AlternateName>EFLP</AlternateName>
      <ReleaseDate>2019-05-05T12:34:56Z</ReleaseDate>
      <Description>The FAST electric field instrument has ten sensors, two on each of the four 29 m radial wire booms (at 24 m and 29 m) and one on each of the two rigid 3 m axial booms. All except the four outermost sensors can also operate as current collecting Langmuir probes. Similar instruments were flown on S3-3, ISEE-1, CRRES, Polar and Cluster. The instrument is designed to provide the following: a vector measurement of the electric field from DC to about 20 kHz over a dynamic range of 0.1 mV/m to 1 V/m with a sampling resolution of 0.03 ms; AC electric field waveform measurements up to 2 MHz with a sampling resolution of 32 ms; continuous monitoring of the dominant frequency and amplitude of high-frequency waves with a time resolution of 0.03 ms; measurement of the thermal plasma density (1-10^5 cm-3) and temperature with up to 0.5 ms and 1 s time resolution, respectively; measurement of the density fluctuations over a dynamic range of 0.1-20 % with a time resolution of at least 1 ms; measurements of time delays between different antennae with time resolution down to 0.03 ms; and wavelength measurements for frequencies up to 20 kHz using on-board interferometric techniques and multiple sensor separations. The FAST electric field instrument stopped providing meaningful data around 2002.</Description>
      <Contact>
        <PersonID>spase://SMWG/Person/Charles.W.Carlson</PersonID>
        <Role>PrincipalInvestigator</Role>
</Contact>
      <InformationURL>
        <Name>NSSDC's Master Catalog</Name>
        <URL>https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1996-049A&amp;ex=3</URL>
        <Description>Information about the Electric Field and Langmuir Probe Experiment experiment on the FAST mission.</Description>
</InformationURL>
</ResourceHeader>
    <InstrumentType>LangmuirProbe</InstrumentType>
    <InvestigationName>Electric Field and Langmuir Probe Experiment on FAST</InvestigationName>
    <ObservatoryID>spase://SMWG/Observatory/FAST</ObservatoryID>
</Instrument>