{
  "Spase": {
    "xmlns:xsi": "http://www.w3.org/2001/XMLSchema-instance",
    "xmlns": "http://www.spase-group.org/data/schema",
    "xsi:schemaLocation": "http://www.spase-group.org/data/schema http://www.spase-group.org/data/schema/spase-2_2_0.xsd",
    "Version": "2.2.0",
    "Instrument": {
      "ResourceID": "spase://SMWG/Instrument/GOES/1/MFM",
      "ResourceHeader": {
        "ResourceName": "Biaxial Fluxgate Magnetometer",
        "ReleaseDate": "2019-05-05T12:34:56Z",
        "Description": "A biaxial, closed-loop, fluxgate magnetometer was deployed on a boom about 0.61 m long. The magnetometer, which had one sensor aligned parallel to the spacecraft spin axis and the other perpendicular to this axis, measured the magnetic field at synchronous altitude. Each sensor had a selectable range (+50, 100, 200, or 400 nT), an offset field capability (plus or minus 1200 nT in 40-nT steps), and an inflight calibration capability.",
        "Contact": [
          {
            "PersonID": "spase://SMWG/Person/Harold.Leinbach",
            "Role": "PrincipalInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Herbert.H.Sauer",
            "Role": "PrincipalInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Joann.Joselyn",
            "Role": "TeamMember"
          },
          {
            "PersonID": "spase://SMWG/Person/Lee.Frost.Bargatze",
            "Role": "MetadataContact"
          }
        ],
        "InformationURL": [
          {
            "Name": "NSSDC Master Catalog",
            "URL": "https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1975-100A-04",
            "Description": "Information about the Biaxial Fluxgate Magnetometer experiment on the GOES 1 mission."
          },
          {
            "Name": "GOES Data Provider Read Me File",
            "URL": "https://satdat.ngdc.noaa.gov/sem/goes/goes_docs/avg/readme.txt",
            "Description": "Caveats and more information about data from this instrument."
          }
        ],
        "PriorID": "spase://SMWG/Instrument/GOES1/MFM"
      },
      "InstrumentType": "Magnetometer",
      "InvestigationName": "Biaxial Fluxgate Magnetometer on GOES 1",
      "ObservatoryID": "spase://SMWG/Observatory/GOES/1"
    }
  }
}