  "Spase": {
    "xmlns:xsi": "http://www.w3.org/2001/XMLSchema-instance",
    "xmlns": "http://www.spase-group.org/data/schema",
    "xsi:schemaLocation": "http://www.spase-group.org/data/schema http://www.spase-group.org/data/schema/spase-2_2_0.xsd",
    "Version": "2.2.0",
    "Instrument": {
      "ResourceID": "spase://SMWG/Instrument/GOES/4/MFM",
      "ResourceHeader": {
        "ResourceName": "Biaxial Fluxgate Magnetometer",
        "AlternateName": "Magnetic Field Monitor (MFM)",
        "ReleaseDate": "2019-05-05T12:34:56Z",
        "Description": "The spinning twin-fluxgate magnetometer was designed to provide the orthogonal components of the magnetic field: Hp was parallel to the spin axis that was held nearly in the direction of Earth's axis, He was directed toward Earth center, and Hn pointed eastward. The magnetometer had a range of +/- 400 nT (without saturation) and a resolution of 0.1 nT over a range of +/- 50 nT. The sensitivity of the magnetometer was about 0.2 nT.",
        "Acknowledgement": "NASA; Dr. Harold Leinbach; Dr. Ernest Hildner; Dr. Joann Joselyn; Dr. Howard J. Singer",
        "Contact": [
          {
            "PersonID": "spase://SMWG/Person/Harold.Leinbach",
            "Role": "PrincipalInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Herbert.H.Sauer",
            "Role": "PrincipalInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Joann.Joselyn",
            "Role": "TeamMember"
          },
          {
            "PersonID": "spase://SMWG/Person/Howard.J.Singer",
            "Role": "PrincipalInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Lee.Frost.Bargatze",
            "Role": "MetadataContact"
          }
        ],
        "InformationURL": [
          {
            "Name": "NSSDC Master Catalog",
            "URL": "https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1980-074A-04",
            "Description": "Information about the Magnetic Field Monitor on the GOES 4 mission."
          },
          {
            "Name": "GOES Data Provider Read Me File",
            "URL": "https://satdat.ngdc.noaa.gov/sem/goes/goes_docs/avg/readme.txt",
            "Description": "Caveats and more information about data from this instrument."
          }
        ]
      },
      "InstrumentType": "Magnetometer",
      "InvestigationName": "Magnetic Field Monitor on GOES 4",
      "ObservatoryID": "spase://SMWG/Observatory/GOES/4",
      "Caveats": "There is no magnetic field data from this instrument."
    }
  }
}