  "Spase": {
    "xmlns:xsi": "http://www.w3.org/2001/XMLSchema-instance",
    "xmlns": "http://www.spase-group.org/data/schema",
    "xsi:schemaLocation": "http://www.spase-group.org/data/schema http://www.spase-group.org/data/schema/spase-2_0_0.xsd",
    "Version": "2.0.0",
    "Instrument": {
      "ResourceID": "spase://SMWG/Instrument/Magsat/VMAG",
      "ResourceHeader": {
        "ResourceName": "Vector Magnetometer",
        "ReleaseDate": "2019-05-05T12:34:56Z",
        "Description": "The vector magnetometer consisted of three fluxgate sensing elements aligned along orthogonal axes. The output of each vector sensor was converted to a digital word by an analog-to-digital converter. The outputs of all these axes were sampled essentially at the same time. Sixteen vectors were measured per second. Each vector measurement had a resolution of better than 1 nT and an absolute accuracy of better than 6 nT rms when referenced to a geocentric coordinate system. The measurement range was plus or minus 6.4E4 nT.",
        "Contact": {
          "PersonID": "spase://SMWG/Person/Robert.A.Langel.III",
          "Role": "PrincipalInvestigator"
        },
        "InformationURL": {
          "Name": "NSSDC's Master Catalog",
          "URL": "https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1979-094A&ex=2",
          "Description": "Information about the Vector Magnetometer experiment on the Magsat mission."
        }
      },
      "InstrumentType": "Magnetometer",
      "InvestigationName": "Vector Magnetometer on Magsat",
      "ObservatoryID": "spase://SMWG/Observatory/Magsat"
    }
  }
}