  <Instrument>
    <ResourceID>spase://SMWG/Instrument/Magsat/VMAG</ResourceID>
    <ResourceHeader>
      <ResourceName>Vector Magnetometer</ResourceName>
      <ReleaseDate>2019-05-05T12:34:56Z</ReleaseDate>
      <Description>The vector magnetometer consisted of three fluxgate sensing elements aligned along orthogonal axes. The output of each vector sensor was converted to a digital word by an analog-to-digital converter. The outputs of all these axes were sampled essentially at the same time. Sixteen vectors were measured per second. Each vector measurement had a resolution of better than 1 nT and an absolute accuracy of better than 6 nT rms when referenced to a geocentric coordinate system. The measurement range was plus or minus 6.4E4 nT.</Description>
      <Contact>
        <PersonID>spase://SMWG/Person/Robert.A.Langel.III</PersonID>
        <Role>PrincipalInvestigator</Role>
</Contact>
      <InformationURL>
        <Name>NSSDC's Master Catalog</Name>
        <URL>https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1979-094A&amp;ex=2</URL>
        <Description>Information about the Vector Magnetometer experiment on the Magsat mission.</Description>
</InformationURL>
</ResourceHeader>
    <InstrumentType>Magnetometer</InstrumentType>
    <InvestigationName>Vector Magnetometer on Magsat</InvestigationName>
    <ObservatoryID>spase://SMWG/Observatory/Magsat</ObservatoryID>
</Instrument>