{
  "Spase": {
    "xmlns:xsi": "http://www.w3.org/2001/XMLSchema-instance",
    "xmlns": "http://www.spase-group.org/data/schema",
    "xsi:schemaLocation": "http://www.spase-group.org/data/schema http://www.spase-group.org/data/schema/spase-2_2_2.xsd",
    "Version": "2.2.2",
    "Instrument": {
      "ResourceID": "spase://SMWG/Instrument/POLAR/CAMMICE-MICS",
      "ResourceHeader": {
        "ResourceName": "Magnetospheric Ion Composition Sensor (MICS) from the Charge and Mass Magnetospheric Ion Composition Experiment (CAMMICE) suite",
        "AlternateName": "CAMMICE-MICS",
        "ReleaseDate": "2019-05-05T12:34:56Z",
        "Description": "The CAMMICE-MICS results include the ion charge state, mass, and incident energy between ~1keV/e to 420keV/e.  The sensor consists of an ogive-shaped electrostatic analyzer, a secondary-electron generation/detection system, and a solid state detector which measure the energy, time of flight, and energy per charge of the incident ions.  Spatial resolution 3 degrees FWHM conical at 90 degrees to the spin axis.  Temporal resolution is 204 seconds for the full spectrum, with a 1/32 spin minimum sample time.  Energy resolution is 15%.  Sensitivity range is from 1 to 5E7 particles/(cm^2*steradian*sec).\n",
        "Contact": [
          {
            "PersonID": "spase://SMWG/Person/Theodore.Allan.Fritz",
            "Role": "PrincipalInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Daniel.N.Baker",
            "Role": "CoInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Richard.D.Belian",
            "Role": "CoInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/J.Bernard.Blake",
            "Role": "CoInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Iannis.A.Daglis",
            "Role": "CoInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Joseph.F.Fennell",
            "Role": "CoInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Manuel.Grande",
            "Role": "CoInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Gerhard.Kremser",
            "Role": "CoInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Christopher.H.Perry",
            "Role": "CoInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Geoffrey.D.Reeves",
            "Role": "CoInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/James.L.Roeder",
            "Role": "CoInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Finn.Soraas",
            "Role": "CoInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Harlan.E.Spence",
            "Role": "CoInvestigator"
          },
          {
            "PersonID": "spase://SMWG/Person/Donald.J.Williams",
            "Role": "CoInvestigator"
          }
        ],
        "InformationURL": [
          {
            "Name": "NSSDC's Master Catalog",
            "URL": "https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1996-013A-06",
            "Description": "Information about the Charge and Mass Magnetospheric Ion Composition Experiment (CAMMICE) Magnetospheric Ion Composition Sensor (MICS) experiment on the Polar mission."
          },
          {
            "Name": "The POLAR CAMMICE Investigation",
            "URL": "https://www-spof.gsfc.nasa.gov/istp/polar/polar_inst.html",
            "Description": "Detailed information concerning CAMMICE MICS and HIT, used to construct instrument description above."
          }
        ]
      },
      "InstrumentType": "EnergeticParticleInstrument",
      "InvestigationName": "Charge and Mass Magnetospheric Ion Composition Experiment (CAMMICE) on Polar",
      "ObservatoryID": "spase://SMWG/Observatory/POLAR"
    }
  }
}